Re: [sap-log-mm] Only 0 Decimal Places are Permitted for Unit of Measure DR with TC CO11N

Posted by PMassey48
on Oct 11 at 1:47 PM
The message is correct in that SAP works with whole units not decimals. In order to overcome this you need to define the smallest whole unit that you will use (at the system level) and then set up a conversion in the material master at the master data level (under additional data).

---------------Original Message---------------
From: Jesus Salazar
Sent: Monday, October 10, 2011 2:05 PM
Subject: Only 0 Decimal Places are Permitted for Unit of Measure DR with TC CO11N

Hi, Friends

I am trying to consume a Backflushing material with CO11N , this material has a UM = DR (with cero decimals), and the quantity is for 0.002 DR, so the systems sent me this error "Only 0 decimal places are permitted for unit of measure DR" , but if I used the MB1A TC , the system run well.

Could somebody help me, please?

Thanks in advance

Regards

Jesus_